TPN telephone
Industrial Telephones TPN
Application TPN non-intrinsically safe telephone sets have been designed for exploitation in hard industrial conditions with no explosion hazard, including mining plants, (extensive humidity, noise, dustiness).
Thanks to the casing resistant to different atmospheric conditions and to lound calling signal, TPN telephones can be utilised in:
- shipyards
- garages
- industrial plants
- building sites
- warehouses
- breweries
Cooperation
With the standard analogue equipment of telephone exchanges of any type.
Power supply
From subscribers' equipment of analogue telephone exchanges.
Versions
Versions
| TPN | basic version |
| TPN-S | version with the optical signaling device |
| TPN-D | version with the additional receiver |
| TPN-SD | version with the optical signaling device and additional receiver |
| TPN-*/CB | version without dialing keypad |
Technical data
| Polarity of the subscriber's line: | optional |
| Direct current resistance: | max. 600Ω |
| Input impedance: | 600Ω |
| Nominal signal level: | 0 dBm |
| Local effect attenuation coefficient: | min. 13dB |
| Calling signal loudness level: | min. 90 dB from 1m distance |
| Dialing: | PM / DTMF |
| Numbers memory: |
|
| Optical calling signal: | visible from long distance |
| Casing protection degree: | IP65 |
| Dimensions: | 275x140x90 mm |
| Weight: | approx. 2.5 kg |
| Operating temperatures range: | from -40 to +40° C |
Documents