ITS system

Local Intrinsically Safe Shaft Telephony System ITS


Application
Local ITS system has been designed to enable the organization of telephone communication in mines' shafts where there are hazardous conditions of methane air atmosphere of any concentration. It enables: connecting and carrying out a telephone conversation within the automatic traffic (CBa) by telephone sets TIG-S, of the main signaler with the level signalmen and another way round, signalmen between themselves, as well as signalmen with the elevator machinist, and the machinist with signalmen, direct (button MW) calling of the machinist from any shaft telephone set TIG-S, immediate direct connection of the machinist with any signal post equipped with a TIG telephone set, the possibility to set a conference connection by the machinist or from the authorized telephone set, the possibility of joining the third party to the conversation on the background of the warning signal, from any shaft telephone set which is connected to the system.

Capacity
Maximum - 14 NN


Power supply
Buffer - 48V DC

Station equipment
ITS rack consisting of:

  • MIKROTEL 150CG telephone exchange
  • intrinsically safe circuits distribution frame
  • 220 V AC/48V DC converter
  • set of free-service batteries
  • separation systems ZSD
  • operator's telephone set

Underground equipment
  • Intrinsically safe mining telephones TIG-S custom made for the ITS system

Documents